9 - 1
9
Serial Programming Commands
The serial programming commands can be used in place of the programming
bar codes. Both the serial commands and the programming bar codes will pro-
gram the scanner. For complete descriptions and examples of each serial pro-
gramming command, refer to the corresponding programming bar code in this
manual.
The device must be set to an RS-232 interface (see page 2-2). The following
commands can be sent via a PC com port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter
A label representing the actual value you should send as part of a
command.
[
option
] An optional part of a command.
{Data} Alternatives in a command.
bold Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage
Prefix Three ASCII characters: SYN M CR (ASCII 22,77,13).
Tag A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS-232 configuration settings
are identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS-232 baud rate is BAD.
Data The new value for a menu setting, identified by the Tag and Sub-
Tag.
Storage A single character that specifies the storage table to which the
command is applied. An exclamation point (!) performs the com-
mand’s operation on the device’s volatile menu configuration table.
A period (.) performs the command’s operation on the device’s
non-volatile menu configuration table. Use the non-volatile table
only for semi-permanent changes you want saved through a power
cycle.

Table of Contents

Other manuals for Honeywell Hyperion 1300G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Hyperion 1300G and is the answer not in the manual?

Honeywell Hyperion 1300G Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor type-
Scanner type1D
Maximum range0.66 m
Read rate (max)270 reads/s
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 70000 lx
Cable length3 m
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption200 mA
SafetyRoHS, CE
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth112 mm
Width79 mm
Height150 mm
Weight160 g

Related product manuals