6 - 7
Code 39
< Default All Code 39 Settings >
Code 39
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters.
Default =
Don’t
Tra nsm it.
Code 39 Check Character
No Check Character indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit only
reads Code 39 bar codes printed with a check character, but will not transmit
the check character with the scanned data.
*On
Off
Transmit
* Don’t Transmit

Table of Contents

Other manuals for Honeywell Hyperion 1300G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Hyperion 1300G and is the answer not in the manual?

Honeywell Hyperion 1300G Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor type-
Scanner type1D
Maximum range0.66 m
Read rate (max)270 reads/s
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 70000 lx
Cable length3 m
Standard interfacesUSB
Connectivity technologyWired
Input voltage5 V
Power consumption200 mA
SafetyRoHS, CE
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth112 mm
Width79 mm
Height150 mm
Weight160 g