EasyManua.ls Logo

Honeywell Hyperion 1300G

Honeywell Hyperion 1300G
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 - 12
Beeper Pitch - Good
Read (Frequency)
Low (1600 Hz) BEPFQ11600 3-2
*Medium (2750 Hz) BEPFQ12750 3-2
High (4200 Hz) BEPFQ14200 3-2
Beeper Duration -
Good Read
*Normal Beep BEPBIP0 3-2
Short Beep BEPBIP1 3-2
Beeper Pitch - Error *Razz (100 Hz) BEPFQ2100 3-3
*Medium (2000 Hz) BEPFQ22000 3-3
High (4200 Hz) BEPFQ24200 3-3
LED - Good Read Off BEPLED0 3-3
*On BEPLED1 3-3
Number of Beeps -
Good Read
*1 BEPRPT1 3-4
Range 1 - 9 BEPRPT# 3-4
Good Read Delay *No Delay DLYGRD0 3-4
Short Delay (500 ms) DLYGRD500 3-4
Medium Delay (1000
ms)
DLYGRD1000 3-4
Long Delay (1500 ms) DLYGRD1500 3-4
User-Specified Good
Read Delay
Range 0 - 30,000 ms DLYGRD##### 3-4
Trigger Mode *Manual/Serial Trigger TRGMOD0 3-5
Read Time-Out (0 -
300,000 ms) *30,000
TRGSTO#### 3-5
Automatic Trigger TRGMOD1 3-5
Presentation Mode TRGMOD3 3-6
Continuous Illumina-
tion On
ILLAON1 3-6
*Continuous Illumina-
tion Off
ILLAON0 3-6
Hands Free Time-Out
(0-300,000 seconds)
*5000
TRG-
PTO######
3-7
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page

Table of Contents

Other manuals for Honeywell Hyperion 1300G