95
Page 95
Mini-AT User Guide
Item
No. Item Name Description
————————————————————————————————————————
056 PULSER A SCALING Scaling factor that determines the volume per pulse for channel
A pulse outputs when item 093 is set to CorVol, UncVol or
PcorVol.
Default = 2.0000
057 PULSER B SCALINGScaling factor that determines the volume per pulse for channel
B pulse outputs when item 094 is set to CorVol, UncVol or
PcorVol.
Default = 2.0000
058 PULSER C SCALING Scaling factor that determines the volume per pulse for channel
C pulse outputs when item 095 is set to CorVol, UncVol or
PcorVol.
Default = 2.0000
059 BATT WAKE CYCLES A number incremented by “1” for each correction-cycle wake-
up, i.e., each meter revolution. The value should be manually
reset back to zero when a new battery pack is installed.
Default = 0
The value also increments during all user accesses and other
actions based on the equivalent wake-cycles listed below.
Action Wake-Cycles (*approx.)
1 meter revolution 1
1 Audit Trail Log Entry 2*
1 minute of Serial Link 1435*
1 minute of Meter Reader 913*
66 Form-A pulses (1-Ch) 14*
240 Form-C pulses (1-Ch) 14*
Midnight roll-over (each day) 6200
060 BATT CYCLES LIM A high limit for the number of wake-up cycles accumulated.
Initiates an alarm (item 100) when exceeded. Intended as early
warning to change-out the main battery pack. If a DCPS is
installed, set item 060 to a value of “0” to disable the alarm
feature. Also, reset item 049 to a value of “6.75” volts
Default = 15,000,000 Alkaline Battery Pack
40,000,000 Lithium Battery Pack
0 DCPS
061 DISPLAY TEST A test pattern that displays all segments and decimal points of
the LCD numeric display. By default, item 061 is the first item
programmed into Mag List 1. This insures that the LCD status
is viewed prior to displaying item values.
Example: 8.8.8.8.8.8.8.8