OMNI-408/OMNI-408EU Installation and Setup Guide
7–10
Digit EXIT TIMEOUTS Digit EXIT TIMEOUTS
0 1 second 8 1 minute 20 seconds
1 10 seconds 9 1 minute 30 seconds
2 20 seconds A 1 minute 40 seconds
3 30 seconds B 1 minute 50 seconds
4 40 seconds C 2 minutes
5 50 seconds D 2 minutes 10 seconds
6 1 minute E 2 minutes 20 seconds
7 1 minute 10 seconds F 3 minutes
Question 08 L3
Burglary Bell Cutoff Default = 5
Enter the desired bell cutoff time on alarm conditions for burglary and panic in 3-minute intervals (for
example, 3 = 9 minutes). The valid range of input is 1 - F, with F indicating an infinite burglary bell
cutoff time.
Digit
BURGLARY & FIRE
BELL TIMEOUTS Digit
BURGLARY & FIRE
BELL TIMEOUTS
1 3 minutes 9 27 minutes
2 6 minutes A 30 minutes
3 9 minutes B 33 minutes
4 12 minutes C 36 minutes
5 15 minutes D 39 minutes
6 18 minutes E 42 minutes
7 21 minutes F Infinite
8 24 minutes
U
L
Must be programmed as “2” for UL installations.
Question 08, L4
Fire Bell Cutoff Default = F
Using the table in Question 08, Location 3 to determine valid choices, enter the desired bell cutoff time
for fire conditions in 3-minute intervals (for example, 3 = 9 minutes). The valid range of input is 1 - F,
with F indicating an infinite fire bell cutoff time.
U
L
Must be programmed as “2” for UL installations.