RAEGuard 3 User Manual
80
Ethyl Acetate
37
2.70
Toluene
35
2.86
Xylene
26
3.85
Acetylene
39
2.56
As for detector calibrated by Methane, for example, if you intend to
monitor Propane, so long as set CF @1.64 in menu of RAEGuard 3,
which appears detector just detects Propane.
If RAEGuard 3 detector is calibrated by non-Methane compounds,
when calibrating with Propane the new CF for Ethane is 1.43/1.64 =
0.87. For example, to detect Ethane with RAEGuard 3, you just set
CF is 0.87, which appears detector is monitor Ethane concentration
real-time.