70 SmartLine Wireless Temperature and Universal I/O User's Manual Revision 1
Name
Description Data Type Data Size
Access Class
DLMO_RADIO_TRANSMIT_POWER Radio maximum transmit level. Int8
1 Read Only Static
DLMO_CHANNEL_DIAG.CHANNEL Channel number.
Uint8 1 Read Only
Dynamic
DLMO_CHANNEL_DIAG.NO_ACK Percentage of transmissions for this channel that did not receive an ACK or NACK.
Uint8 1 Read Only
Dynamic
DLMO_CHANNEL_DIAG.BACKOFF
Percentage of transmissions for this channel aborted due to CCA backoff. Uint8 1
Read Only Dynamic
DLMO_NEIGHBOR_DIAG.RSSI RSSI (Received Signal Strength Indicator) with respect to this neighbor.
Int16 2
Read Only Dynamic
DLMO_NEIGHBOR_DIAG.RSQI RSQI (Received Signal Quality Indicator) with respect to this neighbor.
Uint8 1 Read Only Dynamic
DLMO_NEIGHBOR_DIAG.TX_FAILED Number of failed unicast transmissions to this neighbor. Uint16 2 Read Only Dynamic
DLMO_NEIGHBOR_DIAG.TX_BACKOFF Number of transmissions to this neighbor that were aborted due to CCA backoff. Uint16 2 Read Only Dynamic
DLMO_NEIGHBOR_DIAG.TX_NACK Number of NACKs received from this neighbor. Uint16 2 Read Only Dynamic
DLMO_NEIGHBOR_DIAG.CLOCK_SIGMA Standard deviation of clock corrections with respect to this neighbor. Int16 2 Read Only Dynamic
STAT_PUBSEND Publications from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_PUBRECV Publications from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_READREQSEND Read requests from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_READREQRECV Read requests from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_READREQTIMEOUT Read request timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_READRSPSEND Read response from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_READRSPRECV Read response from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_READRSPTIMEOUT Read response timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_WRITEREQSEND Write request from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_WRITEREQRECV Write requests from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_WRITEREQTIMEOUT Write request timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_WRITERSPSEND Write response from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_WRITERSPRECV Write response from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_WRITERSPTIMEOUT Write response timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_EXECREQSEND Execute request from WDM to field device application. Ui nt32 4 Read Only Dynamic
STAT_EXECREQRECV Execute requests from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_EXECREQTIMEOUT Execute request timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_EXECRSPSEND Execute response from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_EXECRSPRECV Execute response from field device application to WDM. Ui nt32 4 Read Only Dynamic
STAT_EXECRSPTIMEOUT Execute response timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_ALERTREPSEND Alert report from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_ALERTREPRECV Alert report from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_ALERTREPTIMEOUT Alert report timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_ALERTACKSEND Alert acknowledge from WDM to field device application. Uint32 4 Read Only Dynamic
STAT_ALERTACKRECV Alert acknowledge from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_ALERTACKTIMEOUT Alert acknowledge timeouts between WDM and field device application. Uint32 4 Read Only Dynamic
STAT_PUBMISSED Publications missed from field device application to WDM. Uint32 4 Read Only Dynamic
STAT_RESETSTATS Reset statistics. Boolean 1 Read/Write Dynamic
STAT_PUBTIMEOUT Publication timeouts from WDM to field device application. Uint32 4 Read Only Dynamic
Table A-2: Network Level Modbus Table