Page 134 SMV800 Modbus User's Guide Revision 1.0
Totalizer
Engineering
Unit
63
Unit of Totalizer. Depends on
configured flow output type .
When Custom Unit is
selected,
related parameters will be
enabled:
• Custom Unit Tag
• Base Unit
• Base per Custom unit
Conversion factor
RW
uint8
When Flow output type is
Mass Flow, Totalizer Unit
lists:
60 g
61 - Kg
62 - Mton
63 - Lb
64 - ShTons
65 - LTons
125 - Ounce
253 - Custom Unit
When Flow Output type is
Volume Flow, Totalizer
units
lists:
43 - M3
46 - Barrels+J19
112 - Ft3
166 - Nm3
167 - nLiters
41 - Liters
168 - scft
172 - Scm
40 - Gallons
253 - Custom Unit
Flow Custom
Unit Tag
64
User defined Tag for custom
unit selection. This field can
hold numbers, symbols,
upper-case letters
(8 characters)
RW
ASCII
Totalizer Base
Unit
68
Base unit is unit from which
custom unit is derived for
totalizer.
RW
uint8
When Flow output type is
Mass Flow, Totalizer Unit
lists:
60 - g
61 - Kg
62 - Mton
63 - Lb
64 - ShTons
65 - LTons
125 - Ounce
When Flow Output type is
Volume Flow, Totalizer
units
lists:
43 - M3
46 - Barrels+J19
112 - Ft3
166 - Nm3
167 - nLiters
41 - Liters
168 - scft
172 - Scm
40 - Gallons