Status Pwr/
Fan/
Temp
Card Self-
test
Port Net
Fail
Diagnostic Tips
Port Failure
Pwr
Engine:
1. Verify that the node at the other end is up and running.
Fan
Card:
NetFail
2. If this error persists, replace the cable and/or (if ThinLAN)
its terminator.
Status Temp
(one port only)
3. If this error persists, and the port is an Ethernet/802.3
interface, replace the transceiver; if the port is a WAN
interface, verify that its configuration is correct.
4. Initiate the hot-swap self-test by doing either of the
following:
• Hot-swap the card (do steps 1–5 and 8–11 of the
procedure “Replacing an Interface Card [System
Online],” page 3-21).
• Use NCL’s Disable command followed by the
Enable command (see the
Operator’s Reference
).
5. Wait a few seconds for the self-test to complete, then
check the Card and Self-test LEDs.
• If the Card LED remains orange and the Self-test
LED remains green, the card is faulty.
• If the Card LED turns green and the Self-test LED
turns off, call for service from your HP dealer or
service provider.
Note: if this error has occurred, the remaining ports on the
card can be used.
Interface Card Apparently Not Seated During Hot Swap
Pwr
Engine:
Verify that the interface card is seated properly in the router
slot.
Fan
Card:
❋ ❋
Status
Interface Card Self-Test Failure During Hot Swap
Pwr
Engine:
1. Note any error messages in the event log (which can be
displayed from the Main Menu).
Fan
Card:
NetFail
Status Temp
(all ports)
2. Switch the power off and on, then check the LEDs for
failures as indicated in table 3-1.
*
Flashing.
Troubleshooting
Interpreting LED Error Patterns
3-7