Chapter 3 187
Assembly Replacement
Procedure 7. A6A1 High Voltage Assembly (8560E only)
Figure 3-19 A17 CRT Driver Mounting Screws
Replacement
1. Secure the A6A1 high voltage assembly to the A6 power supply
using three panhead screws. Connect ribbon cable A6A1W1 to A6J5.
2. Snap post-accelerator cable A6A1W3 to the CRT assembly.
3. Place the black grommet protecting the post-accelerator cable into
the CRT shield.
4. Ensure that all cables are safely routed and will not be damaged
when securing the A6 cover.
5. Secure the power supply cover shield to the power supply using
three flathead screws (1). See Figure 3-18 on page 184. One end of
the cover fits into a slot provided in the rear frame assembly. Ensure
that the extended portion of the cover shield is seated in the shield
wall groove.
6. Connect A6A1W2 to A17J6.
7. Place the A17 CRT Driver assembly into the center-deck mounting
slot nearest the CRT. Use caution when routing cables to avoid
damage.
8. For Option 007 spectrum analyzers: Place the A16 FADC assembly
into the center-deck mounting slot nearest the left side frame.