A-Class Server Installation
A-Class Server Power Up and Boot Procedures
Chapter 2
55
Configuring the Web Console
To configure the Web console for other A-Class servers, repeat all of the steps in this
section. Use arp -a to display arp entries and use arp-d to delete the previous entry for
IP 192.0.0.192.
For example, to configure the Web Console for A-Class servers with MAC addresses of
0060b0a60ale and 001083a62a3e using a PC with an IP of 15.43.251.93, proceed as
follows:
At the C:\> prompt, type: route add 192.0.0.192 15.43.251.93 and press
Enter.
Using the ping Command At the C:\> prompt, type: ping 192.0.0.192 and press
Enter.
The terminal will display: Pinging 192.0.0.192 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
At the C:\> prompt, type: arp -s 192.0.0.192 00-60-b0-a6-0a-1e
At the C:\> prompt, type: ping 192.0.0.192 and press
Enter.
The terminal will display: Pinging 192.0.0.192 with 32 bytes of data:
Reply from 192.0.0.192: bytes=32 time=10ms TTL=255
Reply from 192.0.0.192: bytes=32 time=10ms TTL=255
Reply from 192.0.0.192: bytes=32 time=10ms TTL=255
Reply from 192.0.0.192: bytes=32 time=10ms TTL=255
Return to Configure the Web Browser and Configure The integrated A-Class Web
Console Software.
Using the arp -a Command At the C:\> prompt, type: arp -a and press
Enter.
The terminal will display:
At the C:\> prompt, type: arp -d 192.0.0.192 and press
Enter.
At the C:\> prompt, type: arp -s 192.0.0.192 00-10-83-a6-0a-1e and press
Enter.
At the C:\> prompt, type: ping 192.0.0.192 and press
Enter.
The terminal will display: Pinging 192.0.0.192 with 32 bytes of data:
Reply from 192.0.0.192: bytes=32 time=10ms TTL=255
Internet
Address
Physical
Address
Type
15.43.248.1 00-00-0c-07-ac-0
0
dynami
c
192.0.0.192 00-60-b0-a6-0a-
1e
static