EasyManua.ls Logo

HP HPE ProLiant DX360 Gen10 - Page 58

HP HPE ProLiant DX360 Gen10
187 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
a. Extend the server from the rack (Extend the server from the rack).
b. Remove the server from the rack (Remove the server from the rack).
4. Remove the access panel (Remove the access panel).
5. Locate any NVDIMMs already installed in the server.
6. Verify that all LEDs on any installed NVDIMMs are o.
7. Install the NVDIMM.
8.
Install and connect the HPE Smart Storage Battery, if it is not already installed.
Installing an energy pack in 8 SFF and 4 LFF configurations
Installing an energy pack in the 10 SFF SAS/SATA/NVMe Combo backplane configuration
9.
Install any components removed to access the DIMM slots and the HPE Smart Storage Battery.
10.
Install the access panel.
11.
Slide or install the server into the rack.
12.
If removed, reconnect all power cables.
13.
Power up the server.
14. If required, sanitize the NVDIMM-Ns. For more information, see
NVDIMM sanitization.
Configuring the server for NVDIMMs
After installing NVDIMMs, configure the server for NVDIMMs. For information on configuring settings for NVDIMMs, see
the HPE 16GB NVDIMM User Guide on the Hewlett Packard Enterprise website (https://www.hpe.com/info/nvdimm-
docs).
The server can be configured for NVDIMMs using either of the following:
Hardware options installation
58

Table of Contents

Related product manuals