EasyManua.ls Logo

HP MSR4080

HP MSR4080
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
132
Examples
# Display power information for GigabitEthernet 2/0/1.
<Sysname> display poe interface power gigabitethernet 2/0/1
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/0/1 15.0 15.3 15.4 Access Point on Room 509 for Peter
# Display power information for all PIs.
<Sysname> display poe interface power
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/0/25 4.4 4.5 4.6 IP Phone in Room 309 for Peter Smith
GE2/0/26 4.4 4.5 15.4 IP Phone in Room 409 for Peter Pan
GE2/0/27 15.0 15.3 15.4 Access Point in Room 509 for Peter
GE2/0/28 0.0 0.0 0.0 IP Phone in Room 609 for Peter John
GE2/0/29 0.0 0.0 0.0 IP Phone in Room 709 for Jack
GE2/0/30 0.0 0.0 0.0 IP Phone in Room 809 for Alien
--- On State Ports: 3; Used: 23.8(W); Remaining: 776.2(W) ---
Table 24 Command output
Field Description
Interface Interface name of a PI.
CurPower Current power of a PI.
PeakPower Peak power of a PI.
MaxPower Maximum power of a PI.
PD Description Type and location description for the PD connected to a PI.
Ports On Number of PIs that are supplying power.
Used Power consumed by all PIs.
Remaining Total remaining power of the system.
display poe power-usage
Use display poe power-usage to display power usage statistics for PoE power supplies and PSEs.
Syntax
Distributed devices in standalone mode/centralized devices in standalone mode:
display poe power-usage
Distributed devices in IRF mode:
display poe power-usage [ chassis chassis-number ]
Centralized devices in IRF mode
display poe power-usage [ slot slot-number ]
Views
Any view

Table of Contents