261
value (action-set view)
Use value to set a value for a set-action object.
Use undo value to restore the default.
Syntax
value integer-value
undo value
Default
The value of a set-action object is 0.
Views
Action-set view
Predefined user roles
network-admin
Parameters
integer-value: Specifies a value for a set-action object. The value is an integer.
Examples
# Set the value to 5 for the set-action object with the OID 1.3.6.1.2.1.2.2.1.7.3.
[Sysname] snmp mib event owner owner1 name EventA
[Sysname-event-owner1-EventA] action set
[Sysname-event-owner1-EventA-set] oid 1.3.6.1.2.1.2.2.1.7.3
[Sysname-event-owner1-EventA-set] value 2
Related commands
action
mib event owner
oid