39
history-record number
Use history-record number to set the maximum number of history records that can be saved for an NQA
operation.
Use undo history-record number to restore the default.
Syntax
history-record number number
undo history-record number
Default
A maximum of 50 records can be saved for an NQA operation.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP operation view
ICMP/UDP echo operation view
UDP tracert operation view
Predefined user roles
network-admin
Parameters
number: Specifies the maximum number of history records that can be saved for an NQA operation. The
value is in the range of 0 to 50.
Usage guidelines
If the number of history records for an NQA operation exceeds the maximum number, earliest history
records are removed.
Examples
# Set the maximum number of history records to 10 for an NQA operation.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] history-record number 10
init-ttl
Use init-ttl to set the TTL value for UDP packets in the start round of the UDP tracert operation.
Use undo init-ttl to restore the default.
Syntax
init-ttl value
undo init-ttl
Default
The NQA client sends a UDP packet with the TTL value 1 to start the UDP tracert operation.

Table of Contents

Other manuals for HP MSR4080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR4080 and is the answer not in the manual?

HP MSR4080 Specifications

General IconGeneral
BrandHP
ModelMSR4080
CategoryNetwork Router
LanguageEnglish

Related product manuals