229
Default
A monitored object does not have a context.
Views
Trigger view
Predefined user roles
network-admin
Parameters
context-name: Specifies a context, a case-sensitive string of 1 to 32 characters.
Usage guidelines
To uniquely identify a monitored object, configure a context for the object.
Examples
# Configure the context contextname1 for a monitored object.
<Sysname> system-view
[Sysname] snmp mib event trigger owner owner1 name triggerA
[Sysname-trigger-owner1-triggerA] context contextname1
Related commands
snmp mib event trigger
wildcard context
delta falling
Use delta falling to set a delta falling threshold.
Use undo delta falling to restore the default.
Syntax
delta falling { event owner event-owner name event-name | value integer-value }
undo delta falling { event | value }
Default
The delta falling threshold is 0, and no falling event is specified.
Views
Trigger-threshold view
Predefined user roles
network-admin
Parameters
event owner event-owner name event-name: Specifies an event by its owner and its name. An event and
the trigger have the same owner. The event-name argument is a case-sensitive string of 1 to 32
characters.
value integer-value: Specifies a delta falling threshold. The value must be smaller than or equal to the
delta rising threshold.