223
Predefined user roles
network-admin
Parameters
entry-number: Specifies a private alarm entry index in the range of 1 to 65535.
prialarm-formula: Configures a private alarm variable formula, a string of 1 to 255 characters. The
variables in the formula must be represented in OID format that starts with a dot (.), for example,
(.1.3.6.1.2.1.2.1.10.1)*8. You can configure a formula to perform the basic math operations of addition,
subtraction, multiplication, and division on these variables. To get a correct calculation result, make sure
the following conditions are all met:
• The values of the variables in the formula are positive integers.
• The result of each calculating step is in the value range for long integers.
prialarm-des: Configures an entry description, a case-sensitive string of 1 to 127 characters.
sampling-interval: Sets the sampling interval in the range of 10 to 65535 seconds.
absolute: Specifies absolute sampling. RMON compares the value of the variable with the rising and
falling thresholds at the end of the sampling interval.
delta: Specifies delta sampling. RMON subtracts the value of the variable at the previous sample from
the current value, and then compares the difference with the rising and falling thresholds.
startup-alarm: Specifies alarms that can be generated when the alarm entry becomes valid. If you do not
specify an alarm, RMON does the following:
• Generates a rising alarm if the first sample crosses the rising threshold.
• Generates a falling alarm if the first sample crosses the falling threshold.
rising: Generates a rising alarm if the first sample after the entry becomes valid is greater than or equal
to the rising threshold.
falling: Generates a falling alarm if the first sample after the entry becomes valid is less than or equal to
the rising threshold.
rising-falling: Generates a rising alarm or falling alarm if the first sample after the entry becomes valid
crosses the rising threshold or falling threshold.
rising-threshold threshold-value1 event-entry1: Sets the rising threshold. The threshold-value1 argument
represents the rising threshold in the range of –2147483648 to +2147483647. The event-entry1 argument
represents the index of the event that is triggered when the rising threshold is crossed. The value range
for the event-entry1 argument is 0 to 65535. If 0 is specified, the alarm does not trigger any event.
falling-threshold threshold-value2 event-entry2: Sets the falling threshold. The threshold-value2 argument
represents the falling threshold in the range of –2147483648 to +2147483647. The event-entry2
argument represents the index of the event that is triggered when the falling threshold is crossed. The
value range for the event-entry2 argument is 0 to 65535. If 0 is specified, the alarm does not trigger any
event.
forever: Configures the entry as a permanent entry. RMON retains a permanent private alarm entry until
it is manually deleted.
cycle cy
cle-per
iod: Sets the lifetime of the entry, in the range of 0 to 4294967 seconds. RMON deletes
the entry when its lifetime expires.
owner text: Specifies the entry owner, a case-sensitive string of 1 to 127 characters.