Hardware options installation 80
Fan population guidelines
Configuration
Fan bay 1
Fan bay 2
Fan bay 3
Fan bay 4
Fan bay 5
One processor, nonredundant
Blank
Fan
Blank
Blank
Fan
One processor, redundant
Blank
Fan
Fan
Fan
Fan
Two processors,
nonredundant
Fan
Fan
Blank
Fan
Fan
Two processors, redundant
Fan
Fan
Fan
Fan
Fan
In a redundant fan mode:
o If one fan fails, the system continues to operate without redundancy. This condition is indicated
by a flashing amber Health LED.
o If two fans fail, the system shuts down.
The minimum fan requirement to make this server bootable is:
o Two fans (fans 2 and 5) for a single processor configuration
o Four fans (fans 1, 2, 4, and 5) for dual processor configuration
Installing the fan option
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
1. Power down the server (on page 20).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 20).
o Remove the server from the rack (on page 22).
4. Remove the access panel (on page 24).
5. Remove the air baffle (on page 28).