Removing and replacing the chassis intrusion detection switchRemoving and replacing the chassis intrusion detection switch
ProcedureProcedure
1. If physically powering down a server with the front bezel installed, remove the front bezel .
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Disconnect following cables from the system board:
14-pin power supply cable
Drive Mini-SAS cable, power Y-cable, and sideband-SATA fan-out cable
9. Remove the chassis intrusion detection switch:
a. Disconnect the chassis intrusion detection switch cable from the system board (callout 1).
b. Press and hold the latches on the DIMM guard (callout 2).
c. While holding the latches, pull the switch from the DIMM guard (callout 3).
d. Detach the cable from the DIMM guard.
To replace the component, reverse the removal procedure.