System Setup and Configuration for Novell NetWare 6
Configuring the Nodes
1. Power on the shared storage (1) and wait for the controllers to initialize.
NOTE: You must power on the Smart Array Cluster Storage before powering on the
servers. After powering on, wait until the storage system startup complete message is
displayed. It may take up to two minutes for the storage system to completely power up.
2. Power on one server, either (2) or (3).
NOTE: Do not use the Option ROM Configuration for Arrays (ORCA) utility to configure
the Smart Array Cluster Storage. The Array Configuration Utility must be used.
While the server boots, the ROM-Based Setup Utility (RBSU) and the ORCA
utility are automatically configured to prepare the server for the operating system
installation. To configure these utilities manually:
— Press the F8 key when prompted during the array controller initialization to
configure the array controller using ORCA.
— Press the F9 key when prompted during the boot process to change the server
settings, such as the settings for language and operating system, using RBSU.
The system is set up by default for the English language and a Microsoft
Windows 2000 installation. Select NetWare 5.x/6 as the operating system.
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide 6-3
HP CONFIDENTIAL Codename: Sopwith Part Number: 252621-002 Last Saved On: 11/8/02 3:00 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL380 G3 with MSA1000 and is the answer not in the manual?

HP ProLiant DL380 G3 with MSA1000 Specifications

General IconGeneral
Rack Height2U
Hard Drive InterfaceUltra320 SCSI
Remote ManagementIntegrated Lights-Out (iLO)
MemoryPC2100 DDR SDRAM
Storage ControllerSmart Array 5i Plus
NetworkDual embedded NC7781 Gigabit NIC
Expansion Slots6 PCI-X (64-bit/100 MHz)
Form FactorRackmount
MSA1000 StorageExternal storage enclosure connected via SCSI
RAID Levels0, 1, 5
Power SupplyRedundant Power Supply Optional
Drive Bays6 hot-plug SCSI bays
Operating System SupportWindows Server, Linux
ProcessorIntel Xeon (up to 3.6 GHz)