System Setup and Configuration for Red Hat Linux 7.3 Professional
LifeKeeper Installation
Proceed with the LifeKeeper installation as instructed in the planning and installation
guide for the specific LifeKeeper Product being installed. Refer to the LifeKeeper for
Linux Release Notes for additional information.
IMPORTANT: The steeleye-lkCCISS-<LifeKeeper Version> package is required for Linux
clustering. Be sure to select this option when selecting packages to install.
IMPORTANT: If prompted to install the CCISS driver during the LifeKeeper for Linux
installation process, answer no. The CCISS driver from HP must be used. Do not confuse the
CCISS driver with the CCISS package that is installed during the LifeKeeper installation
process. The CCISS driver and package are both needed for LifeKeeper for Linux to work
properly.
Validating the LifeKeeper Cluster Configuration
After the systems are configured and the resource hierarchy tree is functional from
within LifeKeeper, system failover should be tested. To test failover:
1. Run the LifeKeeper console GUI on server node B. The console screen shows
server node A as active and server node B in standby.
2. Right-click server node B and select In Service. A window displays as the
scripts are run to switch server node B into service as the active system.
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide 7-7
HP CONFIDENTIAL Codename: Sopwith Part Number: 252621-002 Last Saved On: 11/8/02 3:06 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL380 G3 with MSA1000 and is the answer not in the manual?

HP ProLiant DL380 G3 with MSA1000 Specifications

General IconGeneral
Rack Height2U
Hard Drive InterfaceUltra320 SCSI
Remote ManagementIntegrated Lights-Out (iLO)
MemoryPC2100 DDR SDRAM
Storage ControllerSmart Array 5i Plus
NetworkDual embedded NC7781 Gigabit NIC
Expansion Slots6 PCI-X (64-bit/100 MHz)
Form FactorRackmount
MSA1000 StorageExternal storage enclosure connected via SCSI
RAID Levels0, 1, 5
Power SupplyRedundant Power Supply Optional
Drive Bays6 hot-plug SCSI bays
Operating System SupportWindows Server, Linux
ProcessorIntel Xeon (up to 3.6 GHz)