HP CONFIDENTIAL Codename: Sopwith Part Number: 252621-002 Last Saved On: 11/8/02 3:08 PM
Validating the LifeKeeper Cluster Configuration
After the systems are configured and the resource hierarchy tree is functional from
within LifeKeeper, system failover should be tested. To test failover:
1. Run the LifeKeeper console GUI on server node B. The console screen shows
server node A as active and server node B in standby.
2. Right-click server node B and select In Service. A window displays as the
scripts are run to switch server node B into service as the active system.
3. After server node B is active, right-click server node A and select In Service.
Again, a window displays as the scripts run to make server node A active.
4. After server node A is active, turn off the power to server node A. This initiates a
failure and server node B should become active.
There will be a slight pause before server node B takes over. This is normal
because it takes a few seconds for server node B to see that the heartbeat signal
for server node A is gone.
Configuration is now complete.
IMPORTANT: If the packaged cluster is being transferred, return to “Setup in the
Configuration Fixture” in Chapter 2 or refer to the packaged cluster hardware installation and
configuration poster to complete the process.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL380 G3 with MSA1000 and is the answer not in the manual?

HP ProLiant DL380 G3 with MSA1000 Specifications

General IconGeneral
Rack Height2U
Hard Drive InterfaceUltra320 SCSI
Remote ManagementIntegrated Lights-Out (iLO)
MemoryPC2100 DDR SDRAM
Storage ControllerSmart Array 5i Plus
NetworkDual embedded NC7781 Gigabit NIC
Expansion Slots6 PCI-X (64-bit/100 MHz)
Form FactorRackmount
MSA1000 StorageExternal storage enclosure connected via SCSI
RAID Levels0, 1, 5
Power SupplyRedundant Power Supply Optional
Drive Bays6 hot-plug SCSI bays
Operating System SupportWindows Server, Linux
ProcessorIntel Xeon (up to 3.6 GHz)