Removal and replacement procedures 28
To remove the server from the rack:
1. Pull down the quick-release levers on each side of the server to release the server from the rack. If
necessary, loosen the rack screws.
2. Extend the server on the rack rails until the server rail-release latches engage.
3. Remove the server from the rack.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
To remove the component:
1. Power down the server (on page 26).
2. Extend the server from the rack (on page 26).
3. Remove the access panel. If the locking latch is locked, use a T-15 Torx screwdriver to unlock the
latch.