Removal and replacement procedures 68
Power supply backplane
1. Power down the server (on page 26).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend the server from the rack (on page 26).
4. Remove the processor memory drawer (on page 29).
5. Remove the access panel (on page 28).
6. Remove the power daughter card ("Power daughter board" on page 67).
7. Remove the I/O board ("I/O board" on page 61).
8. Do the following:
a. Using a Torx-10 screwdriver, remove the screws on the top of the backplane.
b. Using a Torx-15 screwdriver, remove the screws at the bottom of the backplane.
c. Remove the backplane.
To replace the component, reverse the removal procedure.
FlexibleLOM
1. Power down the server (on page 26).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove any attached network cables.
4. Extend the server from the rack (on page 26).