EasyManua.ls Logo

HP ProLiant ML30 Gen10 Plus - Page 44

HP ProLiant ML30 Gen10 Plus
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
To replace the component, reverse the removal procedure.
Removing and replacing a hot-plug SFF SAS or SATA driveRemoving and replacing a hot-plug SFF SAS or SATA drive
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
ProcedureProcedure
1. Back up all server data on the drive.
2. Remove the front bezel.
3. Observe the drive LED status and determine if the drive can be removed.
4. Remove the drive.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide 44