Before you perform this procedure, make sure that you have a Phillips No. 1 screwdriver available.
ProcedureProcedure
1. Back up all server data.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
6. Remove the access panel.
7. If installed, remove the air baffle .
8. Disonnect the M.2 SATA SSD cable .
9. Remove the PCI blank retainer.
10. Remove the add-in card.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide 91