EasyManua.ls Logo

HP PROLIANT ML330 G6 - Page 56

HP PROLIANT ML330 G6
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware options installation 56
4.
Remove the air baffle (on page 22).
5. Using a T-15 Torx screwdriver, remove the hard drive cage blank.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
6. Using four of the surplus T-15 screws located on the non-hot-plug hard drive expansion cage, install
the non-hot-plug hard drives.
7. Connect the power and data cables to the non-hot-plug hard drive.
8. Install the non-hot-plug hard drive expansion cage.