Examples
# Display general PSE information.
<Sysname> display poe device
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
7 2 0 24 370 Off LSP2LTSUC
10 3 0 24 370 Off LSP2LTSUC
# (Distributed devices in IRF mode.) Display general PSE information.
<Sysname> display poe device
Chassis 1:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
4 1 0 1 200 Off LSBMPOEGV48TP
7 1 4 8 200 Off LSBMPOEGV48TP
Chassis 2:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
43 10 4 8 200 Off LSBMPOEGV48TP
# (Centralized devices in IRF mode.) Display general PSE information.
<Sysname> display poe device
Slot 1:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
4 1 0 1 200 Off LSBMPOEGV48TP
7 1 4 8 200 Off LSBMPOEGV48TP
Slot 2:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
43 10 4 8 200 Off LSBMPOEGV48TP
Table 21 Command output
Field Description
Chassis 1 Information for member device 1. (Distributed devices in IRF mode.)
Slot 1 Information for member device 1. (Centralized devices in IRF mode.)
PSE ID ID of the PSE.
Slot No. Slot number of the PSE.
SSlot No. Sub-slot number of the PSE.
PortNum Number of PIs on the PSE.
MaxPower(W) Maximum power of the PSE.
State
PSE status:
On—The PSE is supplying power.
Off—The PSE is not supplying power.
Faulty—The PSE has failed.
Model PSE model.