283
Use undo value to restore the default.
Syntax
value integer-value
undo value
Default
The reference value is 0.
Views
Trigger-Boolean view
Predefined user roles
network-admin
Parameters
integer-value: Specifies a reference value in the range of –2147483648 to +2147483647.
Usage guidelines
A Boolean trigger test compares the sampled value with the reference value.
Examples
# Set the reference value to 5 for the Boolean test.
<Sysname> system-view
[Sysname] snmp mib event trigger owner owner1 name triggerA
[Sysname-trigger-owner1-triggerA] test boolean
[Sysname-trigger-owner1-triggerA-boolean] value 5
Related commands
snmp mib event trigger
startup
test
wildcard context (action-set view)
Use wildcard context to enable wildcard search for the contexts of a set-action object.
Use undo wildcard context to restore the default.
Syntax
wildcard context
undo wildcard context
Default
The context of the set action is fully specified.