EasyManua.ls Logo

HPE FlexNetwork MSR958

HPE FlexNetwork MSR958
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
pse pse-id: Specifies a PSE ID. To display PSE ID and slot mappings, use the display poe device
command.
Examples
# Display the status of all PIs on PSE 7.
<Sysname> display poe pse 7 interface
Interface PoE Priority CurPower Oper IEEE Detection
(W) Class Status
GE1/0/1 Enabled Low 4.4 On 1 Delivering
Power
GE1/0/2 Enabled Critical 0.0 Power-lack - Disabled
GE1/0/3 Enabled Low 0.0 Power-deny - Disabled
GE1/0/4 Enabled Critical 0.0 On - Searching
GE1/0/5 Enabled Low 4.0 Power-limit 2 Delivering
Power
GE1/0/6 Enabled Low 0.0 Power-itself - Disabled
GE1/0/7 Disabled Low 0.0 Off - Fault
--- On State Ports: 2; Used: 8.4(W); Remaining: 171.6 (W) ---
Table 27 Command output
Field Description
Interface Interface name of a PI.
PoE
PoE status of a PI:
Enabled.
Disabled.
Priority
Priority of a PI:
Critical (highest).
High.
Low.
CurPower Current power of a PI.

Table of Contents

Other manuals for HPE FlexNetwork MSR958

Related product manuals