2. Install all components removed from the failed system board.
Be sure to install the DIMMs in the same DIMM slots as the failed system board.
3. Install the access panel.
4. Install the power supplies.
5. Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID:
1. During the server startup sequence, press the
key to access UEFI System Utilities.
2. Select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced System ROM Options > Serial
Number, and then press the
key.
3. Enter the serial number and press the
key. The following message appears:
Only qualified service personnel must modify the serial number. This value must always match the serial number on the chassis.
4. To clear the warning, press the
key.
5. Enter the serial number and press the
key.
6. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Date and Time.
7. Select a setting, and then complete your entry:
F9
Enter
Enter
Enter
Enter
HPE ProLiant DL360 Gen11 Server Maintenance and Service Guide 115