1. Observe the following warning:
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components
to cool before touching them.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
5. Remove the access panel .
6. Remove the riser cage.
7. If needed, disconnect the GPU power cable and then remove the GPU from the riser.
The primary riser cage is shown as an example.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the NS204i-u OS boot deviceRemoving and replacing the NS204i-u OS boot device
PrerequisitesPrerequisites
Be sure you have a T-10 Torx screwdriver
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.