6. If installed, remove the butterfly riser cage (Removing a PCIe riser cage on page 39).
7. Remove the air baffle (Removing the air baffle on page 40).
8. To access the DIMM slots for processors 1 and 2, remove the processor mezzanine tray (Removing the
processor mezzanine tray on page 45).
9. Open the DIMM slot latches.
10. Install the DIMM.
11. Install the processor mezzanine tray (Installing a processor mezzanine tray on page 102).
12. Install the air baffle (Installing the air baffle on page 41).
CAUTION:
To avoid damaging the connectors, always install the air baffle into the server before installing the
riser cages.
13. Install the primary PCIe riser cage (Installing the primary PCIe riser cage on page 38).
14. Install the butterfly PCIe riser cage (Installing a butterfly PCIe riser cage on page 80).
15. Install the access panel (Installing the access panel on page 37).
16. Install the server into the rack (Installing the server into the rack on page 53).
17. Connect each power cord to the server.
18. Connect each power cord to the power source.
19. Power up the server on page 32.
To configure the memory mode, use the BIOS/Platform Configuration (RBSU) in the System Utilities.
If a DIMM failure has occurred, see Systems Insight Display combined LED descriptions on page 16.