3. Install the drive.
Installing an NVMe drive
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all device bays are
populated with either a component or a blank.
The server supports installation of up to 20 NVMe drives, depending on the drive cage configuration. Observe
the following population guidelines:
Install a minimum of four NVMe drives in the eight-bay NVMe drive cage.
Two-drive configurations are supported in the following drive cages:
Six-bay HDD/two-bay NVMe (Premium) drive cage
Two-bay SFF (Premium) drive cage in the universal media bay
For more information on valid NVMe drive configurations and cabling, see NVMe drive cable matrix on page
120.
Procedure
1. Remove the drive blank.
Installing an NVMe drive 75