Installing a riser board into the primary PCIe riser cage
Prerequisites
Before installing this option, be sure that you have the following:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Procedure
1. Power down the server on page 32.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack (
Extending the server from the rack on page 32).
• Remove the server from the rack (Removing the server from the rack on page 33).
4. Remove the access panel (Removing the access panel on page 36).
CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the
server in this manner results in improper airflow and improper cooling that can lead to thermal
damage.
5. Disconnect all cables attached to the expansion boards in the PCIe riser cage.
6. Remove the riser cage (Removing a PCIe riser cage on page 39).
7. If installed, remove any expansion boards installed on the riser board.
Installing a riser board into the primary PCIe riser cage 83