System Inlet Temperature, Extended Ambient Operating Support
Specification Value
System Inlet Temperature, Extended Ambient
Operating Support
For approved hardware configurations, the supported
system inlet range is extended to be 5°C to 10°C
(41°F to 50°F) and 35°C to 40°C (95°F to 104°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
For approved hardware configurations, the supported
system inlet range is extended to be 40°C to 45°C
(104°F to 113°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
1
System performance may be reduced if operating in the extended ambient operating range or with a fan
fault.
The approved hardware configurations for this system are listed on the
Hewlett Packard Enterprise
website.
Mechanical specifications
Specification Value
Height 17.48 cm (6.88 in)
Depth 75.18 cm (29.60 in)
Width 44.55 cm (17.54 in)
Weight (maximum) 51.71 kg (114 lbs)
Weight (minimum) 28.12 kg (62 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply on page 153
HPE 1600W Flex Slot Platinum Hot Plug Low Halogen Power Supply on page 153
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/proliant/powersupply).