4. Connect each power cord to the server.
5. Connect each power cord to the power source.
6. Power up the server on page 32.
Removing the fan cage holders
Procedure
1. Power down the server on page 32.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack (Extending the server from the rack on page 32).
• Remove the server from the rack (Removing the server from the rack on page 33).
4. Remove the access panel (Removing the access panel on page 36).
CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the
server in this manner results in improper airflow and improper cooling that can lead to thermal
damage.
5. Remove the fan cage (Removing the fan cage on page 42).
6. Remove the fan cage holders.
44 Removing the fan cage holders