14. Route and connect the cables depending on the server configuration. For more information, see Cabling
on page 118.
CAUTION:
When routing cables, always be sure that the cables are not in a position where they can be
pinched or crimped.
15. Install the fan cage holders (Installing fan cage holders on page 45).
16. Install the fan cage (Installing the fan cage on page 43).
17. If removed, do one of the following:
• Install the processor mezzanine tray (Installing a processor mezzanine tray on page 102).
• Install the 2P pass-through performance board (Installing the 2P pass-through performance board
on page 107).
18. Install the air baffle (Installing the air baffle on page 41).
CAUTION:
To avoid damaging the connectors, always install the air baffle into the server before installing the
riser cages.
19. Install the primary PCIe riser cage (Installing the primary PCIe riser cage on page 38).
20. Install the butterfly PCIe riser cage (Installing a butterfly PCIe riser cage on page 80).
21. Install the access panel (Installing the access panel on page 37).
22. Install the server into the rack (Installing the server into the rack on page 53).
23. Connect each power cord to the server.
24. Connect each power cord to the power source.
25. Power up the server on page 32.
Installing hardware options 61