Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD20 Series Inverters User Manual -127-
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
corresponding value
F05.13
Inflection point 1 reference
of polyline
F05.15-F05.11 0.0% 0.1% ○
F05.14
Inflection point 1
corresponding value
0.0-100.0% 0.0% 0.1% ○
F05.15
Minimum reference of
polyline
0.0%-F05.13 0.0% 0.1% ○
F05.16
Minimum reference
corresponding value of
polyline
0.0-100.0% 0.0% 0.1% ○
F05.17 Skip frequency 1 F00.09-upper limit 0.00Hz 0.01Hz ×
F05.18 Skip frequency 2 F00.09-upper limit 0.00Hz 0.01Hz ×
F05.19 Skip frequency 3 F00.09-upper limit 0.00Hz 0.01Hz ×
F05.20 Range of skip frequency 0.00-30.00Hz 0.00Hz 0.01Hz ×
F05.21
Jog operation frequency
digital setting 2
0.00-upper limit 5.00Hz 0.01Hz ○
Group F06 MS SPEED and Simple PLC (refer to pages 64
68)
F06.00
Multi-step frequency
command 1
F00.09-upper limit 3.00Hz 0.01Hz ○
F06.01
Multi-step frequency
command 2
F00.09-upper limit 6.00Hz 0.01Hz ○
F06.02
Multi-step frequency
command 3
F00.09-upper limit 9.00Hz 0.01Hz ○
F06.03
Multi-step frequency
command 4
F00.09-upper limit 12.00Hz 0.01Hz ○
F06.04
Multi-step frequency
command 5
F00.09-upper limit 15.00Hz 0.01Hz ○
F06.05
Multi-step frequency
command 6
F00.09-upper limit 18.00Hz 0.01Hz ○
F06.06
Multi-step frequency
command 7
F00.09-upper limit 21.00Hz 0.01Hz ○
F06.07
Multi-step frequency
command 8
F00.09-upper limit 24.00Hz 0.01Hz ○
F06.08
Multi-step frequency
command 9
F00.09-upper limit 27.00Hz 0.01Hz ○
F06.09
Multi-step frequency
command 10
F00.09-upper limit 30.00Hz 0.01Hz ○
F06.10
Multi-step frequency
command 11
F00.09-upper limit 33.00Hz 0.01Hz ○
F06.11
Multi-step frequency
command 12
F00.09-upper limit 36.00Hz 0.01Hz ○
F06.12
Multi-step frequency
command 13
F00.09-upper limit 39.00Hz 0.01Hz ○
F06.13
Multi-step frequency
F00.09-upper limit 42.00Hz 0.01Hz ○
A