Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd
134 HD20 Series Inverters User Manual
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
motor 2
F13.26
Slip compensation filter
time of motor 2
0.0110.00s 0.10s 0.01s
F13.27
Slip compensation
limitation of motor 2
0.0250.0% 200.0% 0.1% ×
F13.28
Compensation constant of
motor 2
0.125.0s 2.0s 0.1s
F13.29 Reserved
F13.30 AVR function of motor 2
0: Disabled
1: Enabled all the time
2: Disabled in deceleration
process
1 1
F13.31
Oscillation-suppression
mode of motor 2
0: Oscillation suppression is
dependent on the motor’s
exciting current component
1: Oscillation suppression is
dependent on the motor’s
torque current component
0 1
F13.32
Oscillation-suppression
coefficient of motor 2
0200 50 1
F13.33 Reserved
F13.34 Reserved
F13.35
Speed control proportional
gain 1 of motor 2
0.1200.0 20.0 0.1
F13.36
Speed control integral time
1 of motor 2
0.0010.00s 0.20s 0.01s
F13.37
Speed control proportional
gain 2 of motor 2
0.1200.0 20.0 0.1
F13.38
Speed control integral time
2 of motor 2
0.0010.00s 0.20s 0.01s
F13.39
Speed-loop PI switching
frequency 1 of motor 2
0.0050.00Hz 10.00Hz 0.01Hz
F13.40
Speed-loop PI switching
frequency 2 of motor 2
0.0050.00Hz 15.00Hz 0.01Hz
F13.41
Speed-loop integral
limitation of motor 2
0.0200.0% (F13.03) 180.0% 0.1%
F13.42
Speed-loop differential
time of motor 2
0.001.00s
0.00: There is not the
speed-loop differential
0.00s 0.01s
F13.43
Speed-loop output filter
time of motor 2
0.0001.000s
0.000:The speed-loop filter is
disabled
0.020s 0.001s
F13.44 Reserved
F13.45 Reserved
F13.46
Motor torque limitation
0.0200.0% (F13.03) 180.0% 0.1% ×