CUR MAX
STOP
Maximum permissible current exceeded, contact the manufacturer.
TEMP FET
STOP
If the maximum temperature of the control unit is exceeded, contact
the manufacturer.
20.90 V
BATT OVER 0
Maximum baery voltage exceeded.
17.00 V
BATT EMPTY 1
Baery voltage too low.
19320012
SERVICE A
Tool must go for servicing and is only enabled again aer conrmaon
by the service team.
19320012
SERVICE B
Tool must be calibrated and is only enabled again aer calibraon.
19320012
SERVICE C
Service interval for the threaded mandrel has been reached and it must
be exchanged. The service nocaon must be reset by the service
team in the HST-Tool-Manager.
TARA ERROR
Sensor value error.
Contact manufacturer, tool must be checked.
NA MOTOR
Motor does not start correctly. Motor faulty or incorrect programming.
Check the last step of your program in the pulling direcon. During this
step, Force
actual
must be acvated. Nominal value of the tool must be
entered.