- 41 -
„manual mode acve“ If the checkbox is acvated, the tool works in manual mode. In other
words, the standard program (yellow star) is always executed. In this
mode, the counng funcon, Wi-Fi and barcode are deacvated.
„enable over“
Use the drop-down menu to select how the tool is to be enabled. To use
this function, manual mode must be deactivated.
- „trigger“
The start buon must be pressed 3 mes in quick succession to enable
the tool. The tool then works in the standard program with the counter
acvated.
- „me“
A me must be entered aer which the tool is enabled. The tool then
works in the standard program with the counter acvated.
- „trigger & me“
A combinaon of the funcons described above. The condion that
is reached rst enables the tool. The tool then works in the standard
program with the counter acvated.
- „barcode“
Acvates the barcode scanner in the tool. A barcode must be scanned
to enable the tool. For more informaon on programming barcodes,
see the HST-Tool-Manager's operang instrucons.
- „external control unit“
Acvates the Wi-Fi in the tool. The tool is now enabled by an external
controller. Without being enabled, the tool is locked.
- „barcode & external control unit“
Acvates the barcode scanner and Wi-Fi. The tool scans a barcode
which is then sent to the external controller. Based on the scan, the
tool is enabled via Wi-Fi by the external controller.
„waing me between
ghtenings“
If the funcon is acvated, a me must be entered for the waing me
between two riveng operaons. For this me, the tool is without func-
on between the rivets and does not start up.
„abort on the display“ If the funcon is acvated, a me must be entered for the job to be
cancelled. The yellow menu key must be pressed for this me to cancel
a job.