- 63 -
„record graph I
start
If this checkbox is selected, graphic recording starts from the entered
current value.
„1xNOK → cancel job“ If this checkbox is selected, the program is aborted in the event of an
NOK.

„F
min
F
min
describes the minimum force for this step. If a force below this value
is reached, no rivet has been set. The tool shows "Blank stroke" or "Leer-
hub" on the display, depending on the language seng (see pictures on
page 62).
„pressure trigger The pressure control ensures that the blind rivet can only be processed
when the pressure control is acvated. This prevents accidental trigger-
ing and ensures that the components to be processed are in contact
with each other.
Pressure control is only acve if the checkbox is enabled.
„conrm OK“ If this checkbox is selected, an OK seng must be acknowledged
„record graph F
start
If this checkbox is selected, graphic recording starts from the entered
force value.
„1xNOK → cancel job“ If this checkbox is selected, the program is aborted in the event of an
NOK.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HS-Technik NutBee NBPS-21 and is the answer not in the manual?

HS-Technik NutBee NBPS-21 Specifications

General IconGeneral
BrandHS-Technik
ModelNutBee NBPS-21
CategoryRivet Tools
LanguageEnglish

Related product manuals