89
Failures Instructions
Can’t access
the Internet.
Take the most common access mode as an example, in which a
dial-up application is installed on the user’s computer:
1.
Ensure that any of the problems above is not the reason;
2.
Ensure that the dial-up application is correctly installed and
set on your PC;
3.
Ensure that you have entered the right user name and
password;
4.
Ensure “Use Proxy Server” is set properly for IE, if the
problem still remains even after you have log into
successfully;
5.
Try more than one Web sites, in case of some Web server’s
being in failure.
6.2 FAQs
Q: Why can’t my computer access the Internet, even when
the physical links are well connected?
Check first whether the LEDs are in normal status. If they do,
you have to find help to adjust the settings on the MT800.
Q: I forget the username and password when I am to log
into the Web-based Configuration Manager. Or I just can’t
access the Web-based Configuration Manager.
1) Please press reset button at the rear panel for 3 seconds to
restore the factory default settings of MT800.
2) Indicate your NIC IP address to 192.168.1.3
3) Disable Proxy service.
4) Launch your Web browser and type in http://192.168.1.1