Figure 5-21 SmartLogger networking
NO TE
If a SUN2000 is networked using the SmartLogger, it cannot be connected to a
Smart Dongle.
It is recommended that the number of SUN2000s connected to each RS485 route
be less than 30.
MBUS Communication
The MBUS is a communication mode in which communication signals are loaded
to power cables through the communications board for transmission.
NO TE
Inverters manufactured after July 20, 2022 do not support the AC MBUS.
The built-in MBUS module in the SUN2000 does not need to be connected with cables.
In utility-scale scenarios, an isolation transformer must be connected between inverters
and loads.
Commercial and industrial scenarios are supported only in China.
Figure 5-22 MBUS communication (utility-scale scenarios)
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 5 Electrical Connections
Issue 11 (2023-01-10) Copyright © Huawei Technologies Co., Ltd. 54

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-M3 and is the answer not in the manual?

Huawei SUN2000-M3 Specifications

General IconGeneral
TypeString Inverter
Rated AC Grid Frequency50 Hz / 60 Hz
DC Connection TypeMC4
Protection DegreeIP65
Cooling MethodNatural convection
CategoryInverter
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)≤ 3 %
Operating Temperature Range-25°C to 60°C
CommunicationRS485
Efficiency98%
Protection LevelDC reverse polarity protection, AC overcurrent protection, AC short-circuit protection, Overvoltage protection, Insulation monitoring, Residual current monitoring unit, Arc fault detection