EasyManua.ls Logo

Huawei TaiShan 200 2280 - SAS;SATA Drive Indicators

Huawei TaiShan 200 2280
209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Conguration Maximum
Front Drives
Maximum Rear Drives Drive
Manageme
nt Mode
[1]: The front drives in a server with 25 x 2.5-inch drives in Expander mode or
a server with 8 x 2.5-inch SAS/SATA drives + 12 x 2.5-inch NVMe SSDs can
only be 2.5-inch drives, and the front drives in a server with 12 x 3.5-inch
drives in Expander mode or a server with 12 x 3.5-inch drives in pass-through
mode can only be 3.5-inch drives.
[2]: I/O module 3 supports only 2.5-inch drives, and I/O modules 1 and 2
support 2.5-inch and 3.5-inch drives.
[3]: CPU SAS pass-through requires a SAS riser card. By default, it is installed
on I/O module 2.
[4]: The NVMe SSDs in slots 8 to 19 of a server with 8 x 2.5-inch SAS/SATA
drives + 12 x 2.5-inch NVMe SSDs support only PCIe 3.0.
[5]: Servers with Kunpeng 920 5220 or 3210 processors do not support the
conguration of 24 x 2.5-inch SAS/SATA pass-through drives.
2.6.2 SAS/SATA Drive Indicators
Figure 2-19 shows the SAS/SATA drive indicators.
Figure 2-19 SAS/SATA drive indicators
Table 2-10 Description of SAS/SATA drive indicators
Drive Activity
Indicator (Green
Indicator)
Drive Fault
Indicator (Yellow
Indicator)
Description
Steady on O The drive is in position.
Blinking at 4 Hz O Data is being read or written normally,
or data on the primary drive is being
rebuilt.
Steady on Blinking at 1 Hz The drive is being located by the RAID
controller card.
Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is
being rebuilt.
O Steady on A member drive in the RAID array is
removed.
Steady on Steady on A member drive in the RAID array is
faulty.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 2 Components
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 19

Table of Contents

Related product manuals