Figure 5-64 Installing the RAID controller card
Step 11 Tighten the screws on the RAID controller card. See (2) in Figure 5-64.
Step 12 Connect cables to the RAID controller card. For details, see 3 Internal Cabling.
Step 13 Install the full-height full-length riser module above the RAID controller card. For
details, see 5.11 Riser Module.
Step 14 Install the chassis cover. For details, see 5.8 Chassis Cover.
Step 15 Install the server. For details, see 5.4.3 Installing the Server on Guide Rails.
Step 16 Connect the power cables. For details, see 5.7 PSU.
Step 17 Power on the server. For details, see 5.4.1 Powering On the Server.
Step 18 Log in to the iBMC WebUI, and check whether the new component is normal. For
details, see the
TaiShan Rack Server iBMC User Guide
.
----End
5.15 Supercapacitor
This section uses the server with Kunpeng 920 7260, 5250, or 5230 processors as
an example to describe the internal structure of a server. The procedures for
removing and installing the supercapacitor are the same for the server
congured
with Kunpeng 920 5220 or 3210 processors.
Removing the Supercapacitor
Step 1 Wear an ESD wrist strap. For details, see 5.2 ESD Protection.
Step 2 Power
o the server. For details, see 5.4.2 Powering O the Server.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 5 Removal and Installation
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 127