Automower from 19
1. Function
Low battery voltage Automower will not pass through narrow
passages.
Check all passages in the working area by positioning
the mower beyond the passage, seen in the direction
from the charging station, and press Home. If the mower
does not pass through the passage, change the Corridor
width setting via Garden - Follow loopCorridor width
(shortcut 3-2-3).
The position of the charging station is
unsuitable.
Check that the charging station has been placed as set
out in the installation instructions.
The charging plate (F-coil) is defective. Check the F-signal from the charging station: Place the
Automower in the test position and then check the value
via the Quick check function (Press and hold the
0 key
down for 2
seconds). The F-coil is defective if the value
for F is lower than
300. The charging plate must be
replaced.
Poor contact between the Automower
and the charging station.
Check the charging current from the charging station:
Place the Automower in the test position and then check
the value via the Quick check function (Press and hold
the
0 key down for 2 seconds). Contact is poor if the
current (I) is lower than 1.6
A. Now check the contact
strips on the charging station and charging strips and
charging cabling on the mower.
The battery is spent or defective. When the running time on the mower exceeds
3000
hours the battery is spent.
No contact in charging
station
Let the Automower dock itself in the charging station by
pressing Home. Check that the charging strips and
contact strips make good contact. Also test the charging
current with the help of the Quick check function (press
and hold the
0 key down for 2 seconds). The current (I)
should be at least 1.6
A.
The charging station leans. Check that the charging station does not lean to the side
and that the charging plate is not bent.
Contact between the charging cable’s
cable lugs and the charging strips on the
Automower is poor.
Check the cable lugs. File off any corrosion. Replace the
entire charging cable assembly if necessary.
Contact between the flat-pin connectors
(2) and the contact strips on the charging
station is poor.
Lift off the cover on the charging station and check the
connection.
Contact between the charging strips on
the Automower and the contact strips in
the charging station is poor.
Check that the contact strips on the charging station are
not jammed. Round off the charging strips on the
Automower if necessary using emery cloth and lubricate
with copper paste.
The charging cable connector on the
chassis is defective.
Check that the charging cable connectors and the
charging cables on the mower are undamaged.
The control box on the Automower is
defective.
Replace the control box. See page 108 to replace.
Stuck in charging station An object prevents the Automower from
rolling out of the charging station.
Remove the object.
The contact strips jams. Check that the contact strips on the charging station are
not jammed. Round off the charging strips on the
Automower if necessary using emery cloth and lubricate
with copper paste.
Table 6: Docking error
Fault message Cause of fault message Action/Check

Table of Contents

Other manuals for Husqvarna Automower

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husqvarna Automower and is the answer not in the manual?

Husqvarna Automower Specifications

General IconGeneral
BrandHusqvarna
ModelAutomower
CategoryLawn Mower
LanguageEnglish

Related product manuals