38 Automower from
2. Special menu functions
™
Loop (5-3-4)
Values for the A-signal (Af and Ar), S-signal, F-signal,
N-signal, quality and restarts are shown.
Sensors (5-3-5)
Positions for the collision sensors, lift sensor and tilt
sensor are shown.
Customized (5-3-6)
Customized is a function to determine which four
values are to be shown on the display when real time
data is started. However, the function does not need to
be use other than on the direct request of
Husqvarna
AB.
2.7.4 Demo mode (5-4)
In demo mode the Automower works without starting
the blade disc. The mower varies running with
charging at four minute intervals.
The checkbox is checked when ON is selected.
2.7.5 Loop detection (5-5)
This function makes it possible to temporarily switch
off a mower’s loop detection, i.e. to be able to run it
without the charging station and boundary wire being
installed. Such times include demonstrating an
Automower at the home of a customer.
The checkbox is checked when ON is selected. ON
means the Automower can only work when there is a
loop signal.
The function is switched off automatically when the
mower is switched off and on using the main switch.
NOTE!
Remember to reactive loop detection again.
Operating history
Test
Live data
Demo mode
Loop detection
Special settings
5-4
ON
OFF
5-4-
Operating history
Test
Live data
Demo mode
Loop detection
Special settings
5-5
ON
OFF
5-5-