EasyManuals Logo

Husqvarna Automower Technical Manual

Husqvarna Automower
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
40 Automower from
2. Special menu functions
STOP button override (5-6-4)
When STOP button override is actuated the
Automower can be started and stopped with the help of
the number 0 instead of the STOP button. This function
is suitable when the display is difficult to read on a
working mower, for example, when charging or running
in Live data mode.
The function is switched off automatically when the
mower is switched off and on using the main switch.
Table 7: Factory settings
Function Value (min – max)
Drive past wire 27cm (15 – 50cm)
Reversing distance from charging station 60cm, random ± 20cm (15 – 300cm)
Exit angles 90° – 270° (45° – 315°)
Follow loop out No area activated
Boundary delay 11 minutes
Guide delay 7 minutes
Boundary corridor 6
Guide corridor 6
Timer No limitation
Time lock 30 days
Stop protection Deactivated
Settings lock Deactivated
Square mode cutting (EXP-position) 50% (1% – 100%)
Sounds Keypad LOW
Sounds Operation OFF
Garden shape Normal

Table of Contents

Other manuals for Husqvarna Automower

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husqvarna Automower and is the answer not in the manual?

Husqvarna Automower Specifications

General IconGeneral
BrandHusqvarna
ModelAutomower
CategoryLawn Mower
LanguageEnglish

Related product manuals